We are proud to offer reliable HVAC repair services to homeowners and businesses in Arlington, TX. With the unpredictable Texas weather, it’s crucial to have a functioning heating and cooling system to maintain comfort throughout the year. Our experienced technicians are equipped to handle all types of HVAC issues, from malfunctioning air conditioners to faulty furnaces, ensuring quick and efficient solutions.

Professional HVAC Solutions

We service all major HVAC brands and models, using the latest tools and technology to diagnose and fix problems correctly the first time. Whether you’re dealing with minor repairs or need emergency service, we are dedicated to restoring your system’s performance as quickly as possible.

Reach Out Today

In addition to repairs, we offer preventative maintenance to help you avoid future breakdowns and extend the life of your HVAC system. Our goal is to keep Arlington residents comfortable in every season with expert service and a commitment to customer satisfaction. If you need HVAC repairs in Arlington, TX or any other HVAC services, reach out by calling our team at 972-825-2152.

Most Recent Pins (33)

JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration adjusted a newly installed walk-in freezer in Arlington, Texas. They lowered the temperature from 27 degrees to zero degrees as requested by the customer, ensuring the freezer met the specified cooling requirements efficiently.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration installed a 2.5-ton Trenton condenser and evaporator coil in Arlington, TX. They replaced a leaking system with a faulty compressor using a crane for rooftop installation. The new system runs on 404a refrigerant.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration diagnosed a faulty compressor in a walk-in freezer in Fort Worth, Texas. The compressor was shorted to ground, causing the system to trip the breakers. They identified the issue to restore proper freezer operation.
Check-in Location
JOSEPH HUNTER
A technician installed a new 4-ton Goodman gas furnace in Granbury, Texas. This upgrade improves heating capacity and energy efficiency in residential systems. The installation supports consistent indoor comfort during colder months.
Check-in Location
JOSEPH HUNTER
A technician in Fort Worth, Texas inspected a Carrier package unit after a water leak was reported. The HVAC system was functioning correctly with no leaks found. The issue likely originated from plumbing or roofing, not the unit itself.
Check-in Location
JOSEPH HUNTER
Technicians in Fort Worth, Texas started two walk-in coolers and two package HVAC units. They brazed copper lines, pulled a deep vacuum, and charged the walk-in coolers with R-448 refrigerant to ensure proper refrigeration system operation.
Check-in Location
JOSEPH HUNTER
A technician in North Richland Hills, Texas cleared a clogged drain line and replaced the P-trap on an HVAC system. This service restored proper drainage and helped prevent water buildup, supporting efficient system performance.
Check-in Location
JOSEPH HUNTER
A technician inspected a Carrier AC system in Mansfield, Texas. The condenser fan motor failed due to a bad capacitor, and the system was 7 pounds low on R-410a refrigerant. The technician recommended replacing the coil and condenser to restore proper cooling and prevent further damage.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration installed a 3.5-ton Goodman air conditioning system in Arlington, Texas. The project included setting up a gas furnace, evaporator coil, and condenser to support efficient cooling and heating.
Check-in Location
JOSEPH HUNTER
A technician in Arlington, Texas inspected a Rheem gas furnace and found a failed fan motor. The unit also had no high voltage supply to the condenser. Further electrical service by a licensed electrician is required to restore system functionality.
Check-in Location
JOSEPH HUNTER
A technician replaced a leaking evaporator coil on a Trane air conditioning system. This service restored proper cooling performance and prevented further system damage. The project took place in Grand Prairie, Texas.
Check-in Location
JOSEPH HUNTER
Technicians repaired two rooftop HVAC units in Fort Worth, Texas that were not providing cooling. The units had recently been installed but were not operating due to control board issues. The service restored proper functionality and indoor climate control.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration installed a 4-ton, 15 SEER Trane heat pump with a 15 kW auxiliary heat system in Waxahachie, TX. The system operates on A2L refrigerant 454B, providing efficient heating and cooling.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration repaired a Rudd heat pump by replacing a faulty damper and actuator. The system is now working efficiently. Service location: Mansfield, Texas.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration diagnosed a Daikin gas furnace issue in Mansfield, TX. The system had burned wiring due to flame rollout. Repairs involve replacing the gas valve, adjusting gas pressure, and verifying the flue pipe's clear status to restore safe operation.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration provided heat pump repair in Mansfield, TX. Services included correcting improper wiring, reprogramming thermostats, recommending a new supply and return plenum, and addressing damaged ductwork to restore system functionality.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration repaired burned wires on a 3-ton heat pump's heat kit in Arlington, TX. The system was restored to full functionality, ensuring reliable heating performance for the customer.
Check-in Location
JOSEPH HUNTER
Technicians in Fort Worth, Texas replaced a stolen condenser with a 3-ton RunTru by Trane air conditioning unit. The new system is operating correctly. The contractor also advised future replacement of the air handler to maintain system efficiency.
Check-in Location
JOSEPH HUNTER
A technician replaced a failed capacitor on a three-year-old Carrier air conditioning unit. The system resumed normal cooling after the repair. This AC capacitor replacement service was completed in Crowley, Texas.
Check-in Location
JOSEPH HUNTER
A technician in Grand Prairie, Texas, repaired two Goodman AC units. One unit required an R22 refrigerant refill, while the other had a damaged low-voltage wire. Both indoor units—a wall-mounted and a tub-adjacent unit—were restored to proper working condition.
Check-in Location
JOSEPH HUNTER
A technician in Arlington, Texas, replaced a blown 5-amp fuse in a Goodman gas furnace, checked the system’s operating pressures, and identified a need for approximately 2 pounds of refrigerant. This service ensured safe electrical function and highlighted low refrigerant levels affecting system efficiency.
Check-in Location
JOSEPH HUNTER
A technician inspected a Goodman air conditioner with a First Company air handler and identified that the Nest thermostat was not compatible with the system. The service was completed in Arlington, Texas.
Check-in Location
JOSEPH HUNTER
Technicians installed a new Broan energy recovery ventilator and an ACIQ side discharge heat pump in Arlington, Texas. The setup improves air exchange and supports efficient heating and cooling for the home.
Check-in Location
JOSEPH HUNTER
A technician repaired a Lennox air handler in Arlington, TX by adding 3.5 pounds of refrigerant and cleaning the evaporator coil. The system had a leak in the evaporator coil that affected cooling efficiency. Routine maintenance and refrigerant recharge helped restore proper airflow and temperature control.
Check-in Location
JOSEPH HUNTER
A technician inspected a Trane air conditioning unit and found it low on R-22 refrigerant due to a leak in the evaporator coil. The technician recommended replacing the coil to restore system performance. Service took place in Arlington, Texas.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration inspected two Carrier HVAC systems in Irving, Texas. One system had a failed capacitor and condenser fan motor. The other had a failed blower motor. Due to high repair costs and system age, the technician recommended full system replacements for both units.
Check-in Location
JOSEPH HUNTER
A technician installed a 3.5-ton single-stage Goodman heat pump and air handler in Dallas, Texas. The system uses R-410A refrigerant and is rated at 17 SEER. Additional refrigerant was added to achieve correct subcooling and superheat levels, ensuring efficient system performance.
Check-in Location
JOSEPH HUNTER
A technician serviced a Goodman heat pump in Arlington, Texas. The work included clearing a clogged drain line and adding one pound of R410A refrigerant. The technician advised performing maintenance twice annually to support system performance and prevent issues.
Check-in Location
JOSEPH HUNTER
Pretty Cool AC Heating and Refrigeration installed a 5-ton Run Tru heat pump and a Honeywell T4 thermostat in Arlington, Texas. This service supports efficient residential heating and cooling by replacing outdated systems with new, energy-efficient equipment.
Check-in Location
JOSEPH HUNTER
A technician serviced two Trane air conditioning systems in Haltom City, Texas. The upstairs unit required two pounds of R-410A refrigerant. Both Trane gas furnaces were inspected and confirmed operational. Regular maintenance ensures systems run efficiently and prevents performance issues.
Check-in Location
JOSEPH HUNTER
A technician inspected a 5-ton Rheem heat pump in Arlington, Texas, and found a leak near the muffler. Due to the high cost to repair the leak, they recommended full replacement of the heat pump.
Check-in Location
JOSEPH HUNTER
A technician in Arlington, Texas, completed maintenance on a Goodman GSZH503610AA heat pump. The system is working properly. The service also included installing a float switch and rerouting the condensate drain line to improve drainage efficiency.
Check-in Location
JOSEPH HUNTER
A technician serviced an American Standard heat pump and a Trane air handler in Arlington, Texas. They replaced a faulty capacitor, confirmed the refrigerant level, and noted the need for ductwork adjustments. The system is running properly following the maintenance visit.